Images on Disc Home » Patients » Images on Disc. Following your x-ray, ultrasound or MRI, your images will be electronically sent to one of our doctors for interpretation. Your doctor will also be able to view these images from their clinic. Mac users are able to view their images using OsiriX Lite, which is included on all SRG CDs. Download OsiriX DICOM Medical Image Viewer. Get OsiriX for Mac OS X from the developers website (free) Download OsiriX for Mac OS X through the Mac App Store (free) OsirisX HD for iPad & iPhone ($30 from the iOS App Store) In my case, these DICOM files came from an MRI.
Patient CD/DVD DICOM Viewer Do you know how frustrating it can be to endlessly wait for a patient CD to open? Does your viewer require the installation of additional components before the images can actually be viewed? Try the RadiAnt DICOM Viewer CD/DVD! It is extremely fast, runs from CD/DVD media without installation on Windows XP SP3, Vista, Windows 7, Windows 8, Windows 8.1 and Windows 10 systems and does not have any additional software or programming requirements (e.g.NET, Java). If the user’s operating system permits, the 64-bit version is opened for better efficiency. On older machines the 32-bit version is used.
Approximately just 6MB of overhead data is added to the media. The logo image displayed after opening the application is fully customizable and can be used to show your company information to your clients. All the necessary tools close at hand RadiAnt DICOM Viewer provides the following basic tools for the manipulation and measurement of images:. Fluid zooming and panning.
Brightness and contrast adjustments, negative mode. Preset window settings for Computed Tomography (lung, bone, etc.). Ability to rotate (90, 180 degrees) or flip (horizontal and vertical) images.
Segment length. Mean, minimum and maximum parameter values (e.g. Density in Hounsfield Units in Computed Tomography) within circle/ellipse and its area. Angle value (normal and Cobb angle). Pen tool for freehand drawing.
Quick as lightning RadiAnt DICOM Viewer was designed to use resources as efficiently as possible. It can make use of a multiprocessor and multicore system with large amounts of gigabytes of RAM, but will also run on an old single-core machine with only 512MB RAM. A 64-bit version is provided for modern systems to keep all opened images in more than 4GB of memory, if necessary. Asynchronous reading lets you browse and process images while they are still being opened. All of this is available in one very compact application that has an installer size of just over 2MB. Search and download studies from PACS locations The PACS (Picture Archiving and Communication System) client feature lets RadiAnt DICOM Viewer query and retrieve studies from other PACS hosts. Supported service class users/providers are: C-ECHO SCU, C-ECHO SCP, C-FIND SCU, C-MOVE-SCU, C-STORE-SCP (Only transfers initiated from the RadiAnt DICOM Viewer are accepted.
If you try to send studies from other PACS nodes without searching them first and starting the download in RadiAnt, they will be ignored). Received DICOM files are stored in a temporary folder and are deleted when RadiAnt closes. Supports multiple DICOM file types The software has the capability to open and display studies obtained from different imaging modalities:.
Digital Radiography (CR, DX). Mammography (MG). Computed Tomography (CT). Magnetic Resonance (MR).
Positron Emission Tomography PET-CT (PT). Ultrasonography (US). Digital Angiography (XA). Gamma Camera, Nuclear Medicine (NM).
Secondary Pictures and Scanned Images (SC). Structured Reports (SR) Many types of DICOM images are supported:. Monochromatic (e.g.
CR, CT, MR) and color (e.g. US, 3D reconstructions). Static images (e.g. CR, MG, CT) and dynamic sequences (e.g. XA, US). Uncompressed and compressed (RLE, JPEG Lossy, JPEG Lossless, JPEG 2000). Compare different series or studies Multiple series of one study or several studies can be concurrently opened in the same or different windows for comparison purposes.
Series consisting of images that have been acquired in the same plane (e.g. Computed Tomography series before and after administration of the contrast medium) are automatically synchronized by default. Cross-reference lines are displayed for better correlation of the anatomy when browsing series with different image planes (e.g. Magnetic Resonance study). Multiplanar reconstructions The MPR tool provided within RadiAnt DICOM Viewer can be used to reconstruct images in orthogonal planes (coronal, sagittal, axial or oblique, depending on what the base image plane is). This can help to create a new perception of the anatomy that was not possible to visualize using the base images alone. The reconstruction process is extremely fast: a coronal series can be created from more than 2000 axial CT slices in approximately three seconds (on a modern Intel Core i7 system).
3D volume rendering The 3D VR (volume rendering) tool lets you visualize large volumes of data generated by modern CT/MR scanners in three dimensional space. The different aspects of the data set can be interactively explored in the 3D VR window. This tool lets you rotate the volume, change zoom level and position, adjust color and opacity, measure length and show hidden structures by cutting off the unwanted parts of the volume with the scalpel tool.
The image is rendered progressively to maintain fluid operations even on slower machines. Time-intensity curves RadiAnt DICOM Viewer lets you visualize the lesions' enhancement behavior (e.g. In Breast MRI) by plotting time-intensity curves (TICs).
Different types of curves can be obtained: Ia - straight (the signal intensity continues to increase over the entire dynamic period) / Ib - curved (the time-signal intensity curve is flattened in the late postcontrast period), II - plateau (the signal intensity plateaus in the intermediate and late postcontrast periods) or III - washout (the signal intensity decreases (washes out) in the intermediate postcontrast period). Multi-touch support If you have a Windows 8 or Windows 10 touch-enabled device, you might find that gestures (motions that you make with one, two or more fingers) are easier to use than a mouse or keyboard. RadiAnt DICOM Viewer enables users to make use of the array of multi-touch gestures:.
Touch the image with one finger and move it to browse through images of the displayed series. To zoom in or out, touch two points on the image, and then move your fingers away from or toward each other. Drag the image with two fingers to move it and show invisible parts of zoomed image. You can change the window settings (brightness/contrast) by touching the image with three fingers and moving them up/down (brightness) or left/right (contrast).
Our latest public release (4.6.5) brings a few new features and many improvements:. makes a difference in 3D VR/MIP interactions, if your system is configured with a fast Nvidia GPU. lets you easily identify the same location on multiple 2D series having the same or different image planes. We added some diversity to the 3D VR window - there are available for spicing up your 3D renderings. Finally, you can without the need to initiate the download on the client PC. Our to the latest release. So was the template in the - you can now complete missing items in your translations.
Note: DICOM (an acronym for Digital Imaging and Communications in Medicine) is the most common standard for receiving medical scans. Photoshop allows you to open and work with DICOM (.dc3,.dcm,.dic, or no extension) files. DICOM files can contain multiple “slices” or frames, which represent different layers of a scan. Photoshop reads all frames from a DICOM file and converts them to Photoshop layers.
Photoshop can also place all DICOM frames in a grid on one layer, or open frames as a 3D volume which you can rotate in 3D space. Photoshop can read 8‑, 10‑, 12‑, or 16‑bit DICOM files. (Photoshop converts 10‑ and 12‑bit files to 16‑bit files.) Once you’ve opened a DICOM file in Photoshop, you can use any Photoshop tool to adjust, mark up, or annotate the file. For example, use the Notes tool to add a comment to the file, the Pencil tool to mark a specific area of the scan or the Dust And Scratches filter to remove dust or scratches from a scan. Use the Ruler or selection tools to make measurements of image content. You can view and edit several categories of DICOM metadata in the Photoshop File Info dialog box. Patient data Includes patient name, ID, sex, and date of birth.
Study data Includes study ID, referring physician, study date and time, and study description. Series data Includes series number, modality, series date and time, and series description. Equipment data Includes the equipment institution and manufacturer. Image data Includes the transfer syntax, photometric interpretation, image width and height, bits per pixel, and frames.
(These fields are not editable.).